Commercial fire-rated metal doors are designed for protecting occupants and property by containing fires and preventing their spread. Provide peace of mind and protection with affordable premium fire-rated metal doors from CDF.

Get Instant Pricing For Your Commercial Metal Door!

  • Choose 20, 45, 60, 90, or 180 minute fire rating
  • Complete door, frame, and hardware packages
  • Available in single or double door layouts
  • Select pre-installed glass kit or louver
  • Choose standard or delayed production
  • Fast Track Production ships out in as little as 3 business days!

 

Description

Our fire rated metal doors are crafted with 18-gauge Galvanneal steel for strength, durability, and energy efficiency. These doors are designed for protecting occupants and property by containing fires and preventing their spread.

You'll love our fire rated metal doors for their many great benefits:

  • Fire Rated Options: Available with fire ratings of 20, 45, 60, 90, and 180 minutes.
  • Energy Efficiency: Polystyrene-core metal doors offer excellent insulation. Adding a weatherization kit further improves energy efficiency and helps reduce heating and cooling loss. 
  • Strength and Code Compliance: Ideal for high-traffic commercial environments with the hardware you need and standard commercial metal frames.
  • Safety Features: Try out our safety wire, access control hardware, and meet code regulations with fire ratings up to 3 hours.
  • Quick Production: Our facility in Nashville has our doors in stock, ready to be produced for your project, most projects can ship out in 12 business days, 3 business days with Fast Track Production.
  • Quality and Reliability: We believe in doing it right the first time, on time, every time.

Our fire rated metal doors are a great solution for type of commercial, industrial, or institutional building. Our door experts are ready to help you with your door needs today.

in_stock
Specifications
Brand and Series CDF, Ceco, Curries, Republic, Mesker
Available Colors Primed ready to paint
Core Polystyrene, Honeycombed, Polyurethane
Width 2'0", 2'4", 2'6", 2'8", 2'10", 3'0", 3'6", 3'0", 4'0", 4'8", 5'0", 5'4", 5'8", 6'0", 7'0", 7'4", 8'0", Custom
Height 6'8", 7'0", 8'0", Custom
Hardware Locations Ceco, Curries, Mesker, Pioneer, Republic, Steelcraft, Custom
Fire Rating None, 20 Minute, 45 Minute, 60 Minute, 90 Minute, 3 Hours
Louver No Louver, 12x12 Louver, 24x24 Louver, 24x18 Louver, Custom
Optional Preps Exit Device Trim, Deadbolts, Lite and Louver Cutouts, Continuous Hinge Application, Raceway, Custom
Standard Preps 161 (Cylindrical Lock), 86 Edge (Mortise Lock), Deadbolt, RPD (Blank Edge, Panic Reinforced)
Mfg. Hinge/Lock Location Steelcraft, Mesker, Ceco, Curries, Republic, Baron, Pioneer, Custom Locations
Lite Kit None, 6x27, 12x12, 18x30, 18x60, 24x30, 24x60, Custom
ANSI Standards Meets or exceeds requirements of ANSI A208.1 and CS236-66
Availability In Stock
Undercut 3/4" Standard

Commercial Fire Rated Metal Doors

Our fire rated metal doors are crafted with 18-gauge Galvanneal steel. They're designed with a safety-first mindset, protecting people and property by containing and preventing the spread of fire.

Our doors are supplied from manufacturers that meet the strict guidelines of the steel door institute, as well as testing from Underwriters Laboratories (UL), National Fire Protection Association (NFPA), American National Standards Institute (ANSI), and American Society for Testing and Materials (ASTM).

Metal Door Fire Rating Options

Our commercial-grade fire rated metal doors can withstand the spread of fires to the architectural-grade standard fire rating of 90 minutes. We carry metal fire rated commercial doors with custom options including stain finishes, sizing, and non-existing hardware. The most common applications for a fire rated door include commercial openings needing to meet code requirements or any opening that needs to be protected from a potential fire hazard from spreading.

Two single fire rated metal doors Two single fire rated metal doors
Side shot of five metal doors with five different colored fire labels indicating a various types of fire ratingsSide shot of five metal doors with five different colored fire labels indicating a various types of fire ratings

How Fire Testing Works

Fire testing is completed by independent, internationally recognized agencies that test full door, frame, and hardware assemblies to ensure they meet or exceed regulation standards. Assemblies go through two phases of testing.

Phase One: Door, frame, and hardware assemblies are placed in a furnace. They are exposed to increasing levels of heat, flame, and pressure that simulate a real fire for a specific amount of time.

Phase Two: Once the time has been reached, the assembly is exposed to a stream of cold water or fire suppressant.

In order to pass testing, the assembly must remain secure. View more information on commercial fire rated doors here

Applications and Benefits of Fire Rated Metal Doors 

Applications 

Fire rated metal doors are ideal for protecting people and property in commercial and institutional buildings. Common uses include corridors, stairwells, and any openings that must meet fire code requirements. 

Benefits 

These steel doors contain fires and prevent their spread, giving occupants and property extra protection. With multiple fire rating options, they offer peace of mind while maintaining durability and code compliance. 

All Industry Standard Fire Rated Metal Door Sizes

All commercial fire rated metal doors come at a thickness of 1-3/4". We offer the industry's leading standard widths and heights for your openings. We provide cut down and restyling for custom sized fire rated metal doors to meet any custom opening. Be sure to review our width and height sizing chart before building your quote. If you have any further questions please contact us.

Most Popular Door Sizes

Call Size

Nominal Width

Nominal Height
3068 3'0" (36 inch)
6’8″ (80 inch)
3070
3’0″ (36 inch) 7’0″ (84 inch)

 

Door Sizes |6’8″ Height 

Call Size Nominal Width Nominal Height
2068
2’0″ (24 inch)
6’8″ (80 inch)
2468 2’4″ (28 inch)
6’8″ (80 inch)
2668
2’6″ (30 inch)
6’8″ (80 inch)
2868
2’8″ (32 inch)
6’8″ (80 inch)
21068
2’10” (34 inch)
6’8″ (80 inch)
3468
3’4″ (40 inch)
6’8″ (80 inch)
3668
3’6″ (42 inch)
6’8″ (80 inch)
3868
3’8″ (44 inch)
6’8″ (80 inch)
4068
4’0″ (48 inch)
6’8″ (80 inch)
 

Door Sizes |7’0″ Height

Call Size Nominal Width Nominal Height
2070
2’0″ (24 inch)
7’0″ (84 inch)
2470 2’4″ (28 inch)
7’0″ (84 inch)
2670
2’6″ (30 inch)
7’0″ (84 inch)
2870
2’8″ (32 inch)
7’0″ (84 inch)
21070
2’10” (34 inch)
7’0″ (84 inch)
3470
3’4″ (40 inch)
7’0″ (84 inch)
3670
3’6″ (42 inch)
7’0″ (84 inch)
3870
3’8″ (44 inch)
7’0″ (84 inch)
4070
4’0″ (48 inch)
7’0″ (84 inch)
 

Door Sizes |8’0″ Height 

Call Size Nominal Width Nominal Height
2080
2’0″ (24 inch)
8’0″ (96 inch)
2480 2’4″ (28 inch)
8’0″ (96 inch)
2680
2’6″ (30 inch)
8’0″ (96 inch)
2880
2’8″ (32 inch)
8’0″ (96 inch)
21080
2’10” (34 inch)
8’0″ (96 inch)
3480
3’4″ (40 inch)
8’0″ (96 inch)
3680
3’6″ (42 inch)
8’0″ (96 inch)
3880
3’8″ (44 inch)
8’0″ (96 inch)
4080
4’0″ (48 inch)
8’0″ (96 inch)
 
Actual width is 1/4" under nominal door size, to allow for 1/8" clearance on hinge and strike sides.
Actual height is 7/8" under nominal door size. Standard undercut is 3/4" + 1/8" clearance at top = 7/8"
All doors = 1-3/4″ thickness
*Custom Door Widths and Heights upon Request.
 
Commercial fire rated metal doors specifications chartCommercial fire rated metal doors specifications chart

Fire Rated Metal Door FAQ's

How do I know what fire rating my opening requires?

Fire rating requirements for a fire rated door are set by local building codes and the wall assembly where the fire door will be installed. The rating often depends on the building occupancy, door location, and fire separation design.

Many commercial fire rated doors require ratings such as 20, 45, 60, 90, or 180 minutes. If you are unsure which fire rated door rating your opening requires, your architect, code official, or our door experts can help determine the correct option for your project. Need more details about fire ratings, labels, and testing? View our Fire Rated Door Overview

Are your fire rated metal doors tested and certified?

Yes. Our fire rated metal doors are manufactured and tested to meet industry fire safety standards. These commercial fire rated doors are designed to help meet fire code requirements when installed with properly rated frames and hardware.

Using the correct fire door assembly ensures the door performs as intended during a fire event and helps buildings meet safety and compliance standards.

Can fire rated metal doors include glass or louvers?

Yes. Fire rated metal doors can include approved vision panels or louvers, depending on the door’s fire rating and application. Some fire door configurations allow glass or louvers, while others may have size or placement restrictions.

CDF ProBuilder makes it easy to configure commercial fire rated doors with compliant glass or louver options. The tool helps ensure your fire rated door configuration meets code requirements. Our team can also review your configuration to confirm it meets your project specifications.